The hand dryers requires a 30 x 48 clear floor space and mounted minimum 15 and no higher than 48 from the floor.
Minimum floor space for ada restroom.
For this kind of motion a clear floor space of at least 60 inches in diameter is required allowing a 180 degree turn.
A full length mirror in the restroom fulfills the ada requirement for mirrors if it s not possible to mount the mirror at 40 inches above the floor.
Doors can swing into the turning space.
30 x 48 760 x 1220 mm of clear floor space is required in every restroom.
In some cases the available clear space can be supplemented by open space under a fixture to meet the minimum requirement.
Soap dispensers should be mounted no higher than 44 above the floor.
When 30 x 48 760 x 1220 mm clear floor space is provided beyond the arc of the door swing shaded area to right of door opening the door is permitted to swing into the clear floor space or clearance required for any fixture.
The adaag states that mirrors need to be mounted with the bottom edge of the reflecting surface no higher than 40 inches above the floor with the top edge at a minimum of 74 inches from the floor.
An accessible lavatory may overlap the clear floor space at the back wall as long as a minimum 18 inches 455 mm clearance is maintained between the centerline of the water closet and the nearest edge of the lavatory.
A clear circle of at least 60 around the side wall and 56 from the rear wall to allow a wheelchair to turn the door cannot swing into the minimum required area for wheelchair accessible toilet compartments.
A single wheelchair must be able to rotate freely inside a bathroom.
In the 2010 standards an exception allows the entry door to swing over the clear floor spaces and clearances required at the fixtures if a clear floor space complying with section 305 3 minimum 30 inches by 48 inches is provided outside the arc of the door swing section 603 3 3 exception 2.
Clearances are required at accessible elements fixtures and controls so that people with disabilities including those who use wheelchairs can approach and use them.
At least one sink or lavatory in the bathroom must be at a minimum 29 inches off the floor and must not exceed a height of 34 inches.
The height of toilet seats that meet ada requirements range from 17 inches to 19 inches off the floor.
Multiple toilet stall layouts.
An example of a single ada bathroom layout.
Grab bars are provided on the side and back wall see figure here under.
They cannot swing into the clearance required at plumbing fixtures except in single user toilet rooms where clear floor space 30 minimum by 48 minimum is provided in the room beyond the arc of the door swing 603 2 3 ex.